{"title":"MANIFOLD CONTROL PACK","description":null,"products":[{"product_id":"underfloor-heating-blending-valve-with-bastion-7-5m-pump","title":"UNDERFLOOR HEATING BLENDING VALVE WITH BASTION 7.5M PUMP","description":"\u003ch1\u003e\u003cspan\u003eUNDERFLOOR HEATING MIXING VALVE WITH BASTION 7.5M HEAD CIRCULATION PUMP\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eTHIS UNDERFLOOR HEATING MIXING VALVE ASSEMBLY COMBINES A COMPACT THERMOSTATIC TEMPERATURE CONTROL VALVE WITH AN ENERGY-EFFICIENT, A-RATED BASTION CIRCULATION PUMP FEATURING A 7.5M MAXIMUM HEAD. DESIGNED FOR WATER-BASED UNDERFLOOR HEATING SYSTEMS, IT PROVIDES ACCURATE FLOW TEMPERATURE REGULATION AND RELIABLE WATER CIRCULATION.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSUPPLIED AS A FULLY ASSEMBLED LEFT-HAND UNIT, IT FEATURES G1 MALE SWIVEL CONNECTIONS WITH FLAT SEALS, ALLOWING DIRECT CONNECTION TO THE MANIFOLD WITHOUT MOUNTING BRACKETS, DRILLING, OR ADDITIONAL FIXING HARDWARE.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTHE THERMOSTATIC MIXING VALVE OFFERS AN ADJUSTABLE FLOW TEMPERATURE RANGE OF \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e35–65°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, WITH A FACTORY PRESET OF \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e45°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. TEMPERATURE ADJUSTMENTS ARE MADE USING THE CONTROL KNOB: TURN CLOCKWISE TO INCREASE THE TEMPERATURE OR ANTICLOCKWISE TO DECREASE IT. THIS HELPS MAINTAIN CONSISTENT, COMFORTABLE FLOOR HEATING WHILE REDUCING THE RISK OF EXCESSIVE TEMPERATURES. THE UPGRADED BASTION 7.5M HEAD PUMP PROVIDES ENHANCED CIRCULATION CAPACITY FOR A WIDER RANGE OF SYSTEM CONFIGURATIONS WHILE MAINTAINING LOW ELECTRICITY CONSUMPTION.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKEY FEATURES\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eADJUSTABLE THERMOSTATIC MIXING VALVE:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e PROVIDES PRECISE UNDERFLOOR HEATING FLOW TEMPERATURE CONTROL BETWEEN 35°C AND 65°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eENERGY-EFFICIENT BASTION CIRCULATION PUMP:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e A-RATED PUMP WITH A 7.5M MAXIMUM HEAD, POWER CONSUMPTION OF 5–39W, AND A QUIET CANNED-MOTOR DESIGN.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMULTIPLE OPERATING MODES:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e INCLUDES AUTO ADAPTATION, PROPORTIONAL PRESSURE, CONSTANT PRESSURE, AND CONSTANT-SPEED SETTINGS, WITH PWM COMPATIBILITY.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDIRECT MANIFOLD CONNECTIONS:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e G1 MALE SWIVEL UNIONS WITH FLAT SEALS PROVIDE A SECURE CONNECTION AND SIMPLIFY INSTALLATION.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBRACKET-FREE INSTALLATION:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e THE COMPACT, LIGHTWEIGHT ASSEMBLY ALLOWS FLEXIBLE POSITIONING WITHOUT THE NEED FOR SEPARATE SUPPORT BRACKETS.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eINSTALLATION-READY PUMP:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e SUPPLIED WITH A PRE-WIRED THREE-CORE ELECTRICAL LEAD AND 25MM GASKETS.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCOMPATIBILITY WITH MULTIPLE HEAT SOURCES:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e SUITABLE FOR SYSTEMS POWERED BY GAS OR OIL BOILERS, WOOD-BURNING STOVES, SOLAR HEATING, AND GROUND-SOURCE OR AIR-SOURCE HEAT PUMPS.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eBENEFITS AND INSTALLATION GUIDANCE\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eQUICK AND STRAIGHTFORWARD INSTALLATION:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e THE ASSEMBLY CONNECTS DIRECTLY TO THE MANIFOLD, HELPING REDUCE INSTALLATION TIME. IT IS IDEAL FOR RETROFIT PROJECTS, SINGLE-ZONE UPGRADES, SMALL TO MEDIUM-SIZED ROOMS, HOME EXTENSIONS, AND SYSTEMS REQUIRING ADDITIONAL CIRCULATION CAPACITY.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eIMPROVED CIRCULATION PERFORMANCE:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e THE PUMP'S 7.5M HEAD CAPABILITY MAKES IT SUITABLE FOR INSTALLATIONS WITH HIGHER HYDRAULIC RESISTANCE OR LARGER HEATING ZONES, HELPING ACCOMMODATE MORE DEMANDING UNDERFLOOR HEATING LAYOUTS WITHOUT NECESSARILY REQUIRING AN ADDITIONAL PUMP.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLOWER ENERGY CONSUMPTION:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e THE A-RATED CIRCULATION PUMP AND ACCURATE TEMPERATURE BLENDING HELP MINIMISE ENERGY USE. THE ASSEMBLY IS ALSO SUITABLE FOR LOW-TEMPERATURE HEATING SYSTEMS INCORPORATING RENEWABLE ENERGY SOURCES.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCOMFORTABLE AND CONTROLLED HEATING:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e REGULATING THE WATER TEMPERATURE SUPPLIED TO THE FLOOR HELPS MAINTAIN EVEN HEAT DISTRIBUTION AND REDUCES THE RISK OF OVERHEATING. THE FACTORY SETTING OF 45°C PROVIDES A CONVENIENT STARTING POINT FOR MANY UNDERFLOOR HEATING APPLICATIONS, ALTHOUGH THE FINAL SETTING SHOULD COMPLY WITH THE SYSTEM DESIGN REQUIREMENTS AND FLOORING MANUFACTURER'S TEMPERATURE LIMITS.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Happy Waves","offers":[{"title":"Default Title","offer_id":55688358527318,"sku":null,"price":145.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1070\/8310\/4598\/files\/Blending-Valve-with-Bastion-Pump.jpg?v=1791654644"},{"product_id":"underfloor-heating-blending-valve-with-grundfos-upm3-flex-pump","title":"UNDERFLOOR HEATING BLENDING VALVE WITH GRUNDFOS UPM3 FLEX PUMP","description":"\u003ch1\u003e\u003cspan\u003eUNDERFLOOR HEATING CONTROL PACK WITH GRUNDFOS UPM3 PUMP\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eDESIGNED FOR HEATING LOADS OF UP TO 15KW, THIS COMPACT, LIGHTWEIGHT CONTROL PACK IS EQUIPPED WITH A GRUNDFOS CIRCULATION PUMP FOR DIRECT MANIFOLD CONNECTION. SUPPLIED FULLY ASSEMBLED IN A LEFT-HAND CONFIGURATION, IT FEATURES G1 MALE SWIVEL CONNECTIONS WITH FLAT SEALS AS STANDARD.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTHE PRACTICAL DESIGN AND SWIVEL UNION CONNECTIONS ALLOW THE UNIT TO BE FITTED DIRECTLY TO THE MANIFOLD WITH MINIMAL INSTALLATION EFFORT. AS NO ADDITIONAL SUPPORT BRACKETS ARE REQUIRED, THERE IS NO NEED FOR EXTRA DRILLING OR FIXING POINTS, HELPING TO SIMPLIFY THE INSTALLATION PROCESS.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTHE INTEGRATED THERMOSTATIC MIXING VALVE ALLOWS THE UNDERFLOOR HEATING FLOW TEMPERATURE TO BE ADJUSTED WITHIN A RANGE OF 35–65°C. THE CONTROL PACK IS COMPATIBLE WITH A WIDE VARIETY OF HEAT SOURCES, INCLUDING OIL AND GAS BOILERS, WOOD-BURNING STOVES, SOLAR HEATING SYSTEMS, AND GROUND-SOURCE OR AIR-SOURCE HEAT PUMPS.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEACH ASSEMBLY IS SUPPLIED WITH A THERMOSTATIC MIXING VALVE, AN A-RATED GRUNDFOS UPM3 FLEX CIRCULATION PUMP, A MANIFOLD ADAPTER, AND THE REQUIRED SEALING COMPONENTS.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eHOW DOES THE SYSTEM WORK?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eIN A WATER-BASED UNDERFLOOR HEATING SYSTEM, THE CIRCULATION PUMP AND THERMOSTATIC MIXING VALVE WORK TOGETHER TO PROVIDE CONTROLLED WATER FLOW AND MAINTAIN SUITABLE OPERATING TEMPERATURES. EACH COMPONENT PERFORMS A DIFFERENT BUT EQUALLY IMPORTANT FUNCTION.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCIRCULATION PUMP\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e1. CONTINUOUS WATER CIRCULATION\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTHE PUMP DRIVES WATER AROUND THE UNDERFLOOR HEATING CIRCUIT, MOVING WARM WATER FROM THE HEATING SOURCE, SUCH AS A BOILER OR HEAT PUMP, THROUGH THE PIPEWORK INSTALLED BENEATH THE FLOOR. THE COOLED WATER THEN RETURNS TO THE CIRCUIT TO BE REHEATED AND RECIRCULATED.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e2. CONSISTENT HEAT DISTRIBUTION\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBY MAINTAINING WATER CIRCULATION THROUGH THE HEATING LOOPS, THE PUMP HELPS DISTRIBUTE HEAT ACROSS THE FLOOR MORE EVENLY. THIS SUPPORTS A COMFORTABLE INDOOR ENVIRONMENT AND REDUCES THE LIKELIHOOD OF UNEVEN HEATING BETWEEN DIFFERENT AREAS.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTHERMOSTATIC MIXING VALVE\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e1. PRECISE FLOW TEMPERATURE REGULATION\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTHE MIXING VALVE CONTROLS THE TEMPERATURE OF THE WATER ENTERING THE UNDERFLOOR HEATING CIRCUITS. IT ACHIEVES THIS BY BLENDING HOT WATER FROM THE HEAT SOURCE WITH COOLER WATER RETURNING FROM THE FLOOR HEATING SYSTEM, PRODUCING A SUITABLE FLOW TEMPERATURE FOR THE INSTALLATION.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e2. PROTECTION AGAINST EXCESSIVE TEMPERATURES\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUNDERFLOOR HEATING GENERALLY OPERATES AT LOWER WATER TEMPERATURES THAN MANY HEAT SOURCES CAN PRODUCE. THE MIXING VALVE HELPS REDUCE THE TEMPERATURE OF THE SUPPLY WATER TO AN APPROPRIATE LEVEL, LIMITING THE RISK OF FLOOR OVERHEATING AND HELPING MAINTAIN COMFORTABLE ROOM CONDITIONS.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWORKING TOGETHER FOR EFFICIENT HEATING\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eTHE CIRCULATION PUMP AND MIXING VALVE FORM AN IMPORTANT PART OF AN EFFECTIVE WATER-BASED UNDERFLOOR HEATING SYSTEM. THE PUMP MAINTAINS WATER MOVEMENT THROUGH THE CIRCUITS, WHILE THE MIXING VALVE REGULATES THE SUPPLY TEMPERATURE TO SUIT THE SYSTEM'S REQUIREMENTS.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWHEN CORRECTLY SELECTED, INSTALLED, AND MAINTAINED, THESE COMPONENTS HELP SUPPORT RELIABLE OPERATION, CONSISTENT HEAT DISTRIBUTION, AND EFFICIENT ENERGY USE. APPROPRIATE SYSTEM SIZING AND TEMPERATURE SETTINGS ARE ESSENTIAL FOR ACHIEVING COMFORTABLE HEATING PERFORMANCE WHILE PROTECTING THE FLOORING AND OTHER SYSTEM COMPONENTS.\u003c\/span\u003e\u003c\/p\u003e","brand":"Happy Waves","offers":[{"title":"Default Title","offer_id":55688372781398,"sku":"HW-PUMPGF-PK","price":185.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1070\/8310\/4598\/files\/grundfos-upm3-flex-as-thermostatic-mixing-valves-the-under-floor-heating-company.jpg?v=1791655238"}],"url":"https:\/\/happywaves.co.uk\/collections\/manifold-control-pack.oembed","provider":"Happy Waves","version":"1.0","type":"link"}